vTanis userman 302708 Revision 12
© Copyright actidata 2011 Page 21 of 112
Product installation
General installation considerations
This chapter provides instructions for installing the vTanis.
Adhere strictly the following steps to install the vTanis product:
Selecting a location
Select a location that meets the following criteria:
Horizontal only-either sitting on a table top or mounted in a 19”
equipment rack via the included rack mount ears. The vTanis weighs 15.7
lbs (7.1 kg) when fully populated with cartridges and must be placed on
or mounted in a system capable of supporting this weight
Standard EIA rack pitch-2U high space
Room temperature
Operating
Non-operating
+10° - +40° C, gradient 10°C/hour
- 30° - +60° C, gradient 20°C/hour
100-240 VAC input voltage
50-60 Hz line frequency
1.2-0.6 A
Locate the vTanis within 6 ft. of an AC outlet.
The AC power cord is the vTanis main AC disconnect device and must be